Product List

Updated : 04/02/21

Awning Windows

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value SHGC CR STC OITC Impact/ Blast
Brighton Awning
Wood
6"
R-50
48 x 24
50
0.05
7.52
75.19
0.28-0.32
0.12-0.28
40-56
--
--
C600 Awning
Aluminium
4.125”
AW-PG70-AP
48 x 72
105.26
<0.30
12.11
105.26
0.19-0.30
0.11-0.44
50-80
28-41
28-35
C700 Awning
Aluminium
4.125”
AW-PG70
48 x 72
105.26
<0.30
12.11
105.26
0.19-0.30
0.11-0.44
50-80
28-41
28-35
Impact
E600 Awning
Aluminum
3.25”
AW-PG70
60 x 36
70
<0.10
12.11
105.26
0.32-0.36
0.10-0.41
56 (Energy Basic)
--
--
H450 Awning
Aluminum
3.25”
CW-70
60 x 36
70
<0.10
10
105
0.40-0.60
0.14-0.59
57 (Energy Basic)
--
--
M600 Awning
Aluminum
3.25”
AW-PG70-AP
48 x 72
70
0.06
12.11
70.18
0.43
0.19-0.29
42-49
--
--
M700 Awning
Aluminum
3.25”
AW-PG70-AP
48 x 72
70
0.06
12.11
70.18
0.43
0.19-0.29
42-49
--
--
Impact
T600 Awning
Aluminum
3.25"
AW-PG70
60 x 36
70
<0.10
12.11
105.26
0.41-0.45
0.12-0.41
46 (Energy Basic)
--
--
V200 Awning
Vinyl
3.25”
R-40
48 x 18
60.15
0.03
6.06
60.15
0.23-0.27
--
--
--
--
V250 Awning
Vinyl
3.25”
LC-35
36 x 72
50
<0.30
7.52
75.19
0.23 - 0.27
0.12-0.28
--
--
--
V300 Awning
Vinyl
3.25”
CW-50
60 x 32
75.19
0.01
7.50
75.19
0.23-0.27
0.11-0.27
58 (Energy Basic)
35
29
V700 Awning
Vinyl
3.25”
CW-50
48 x 32
75.19
0.01
7.5
75.19
0.24-0.28
0.11-0.41
--
--
--
Impact
W600 Awning
Wood
5.625"
AW-PG70-AP
48 x 72
105.26
0.09
12.11
105.26
0.17-0.29
0.11-0.44
48-77
27-44
22-35

Casement Windows

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value SHGC CR STC OITC Impact/ Blast
Brighton Casement
Wood
6"
LC-60
36 x 72
60
<0.01
9.19
90.23
0.28-0.32
0.12-0.28
45-58
--
--
Brighton Fixed Casement
Wood
6"
LC-50
72 x 72
50
<0.01
7.52
75.19
0.25-0.29
0.14-0.33
44-57
--
--
C600 Casement
Aluminum
4.125"
AW-PG70-C
48 x 84
105.26
0.02
12.11
105.26
0.19-0.30
0.11-0.44
51-80
28-41
28-35
C700 Casement
Aluminum
4.125"
AW-PG70
48 x 84
120.30
<0.10
12.11
105.26
0.19-0.30
0.11-0.44
51-80
28-41
28-35
Impact
E600 Casement
Aluminum
3.25”
AW-PG70
36 x 72
70
<0.10
12.11
105.26
0.32-0.39
0.12-0.26
56 (Energy Basic)
31-42
25-34
H450 Casement
Aluminum
3.25”
CW-90
36 x 60
90
<0.10
10
105
0.39-0.44
0.14-0.48
--
--
--
M600 Casement
Aluminum
3.25”
M700 Casement
Aluminum
3.25”
T600 Casement
Aluminum
3.25”
V200 Casement
Vinyl
3.25”
V250 Casement
Vinyl
3.25”
V300 Casement
Vinyl
3.25”
V700 Casement
Vinyl
3.25”
W600 Casement
Wood
5.625”

Doors

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value SHGC CR STC OITC Impact/ Blast
Brighton Hinged (inswing)
Wood
Brighton Hinged (Outswing)
Wood
Brighton Sliding (French Rail)
Wood
Brighton Sliding (Narrow Rail)
Wood
M300 Sliding
M600 Sliding
M600 Terrace (Inswing)
M600 Terrace (Outswing w/low profile)
M600 Terrace (Outswing)
V100 Sliding
V250 Sliding

Fixed Windows

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value SHGC CR STC OITC Impact/ Blast
Brighton Fixed
Wood
6"
LC-60
36 x 72
60
<0.01
9.19
90.23
0.28-0.32
0.12-0.28
45-58
--
--
Brighton Fixed Casement
Wood
6"
LC-50
72 x 72
50
<0.01
7.52
75.19
0.25-0.29
0.14-0.33
44-57
--
--
C600 Fixed
Aluminum
4.125"
AW-PG80-F
72 x 120
120.30
<0.10
12.11
120.30
0.15-0.29
0.13-0.57
51-81
28-41
28-35
C700 Fixed
Aluminum
4.125"
AW-PG70
72 x 120
120.30
<0.10
12.11
120.30
0.15-0.29
0.13-0.57
51-81
28-41
28-35
Impact

Hopper Windows

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value CR STC OITC Impact/ Blast
C600 Awning
Aluminium
3.23”
CW-70
60 x 36”
70
<0.10
12 (projected)
105
88 (Energy basic)
120
11
120 (project)
C600 Awning
Aluminium
3.23”
CW-70
60 x 36”
70
<0.10
12 (projected)
105
88 (Energy basic)
120
11
120 (project)

Horizontal Sliding Windows

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value SHGC CR STC OITC Impact/ Blast
C600 Awning
Aluminium
3.23”
CW-70
60 x 36”
70
<0.10
12 (projected)
105
88 (Energy basic)
120
11
120 (project)
C600 Awning
Aluminium
3.23”
CW-70
60 x 36”
70
<0.10
12 (projected)
105
88 (Energy basic)
120
11
120 (project)

Hung Windows

Series/Model Name Material Type Frame Depth Rating Test size (Inches) Design Pressure Air Infiltiration Water Resistance Structural Overload U-Value SHGC CR STC OITC Impact/ Blast
Brighton Awning
C600 Awning
C700 Awning
E600 Awning
E600 Awning
H450 Awning
M600 Awning
M600 Awning
M700 Awning
T600 Awning
V200 Awning
V250 Awning
V300 Awning
V700 Awning
W600 Awning